Lenovo 3000 K100 Hardware Maintenance Manual page 47

Hide thumbs Also See for 3000 K100:
Table of Contents

Advertisement

Diagnostic Error Code
035-000-XXX
RAID interface Test Passed
035-0XX-XXX
RAID interface Failure
035-195-XXX
RAID interface Test aborted by user
035-196-XXX
RAID interface test halt, error
threshold exceeded
035-197-XXX
RAID interface test warning
035-198-XXX
RAID interface test aborted
035-199-XXX
RAID interface test failed, cause
unknown
071-000-XXX
Audio port Interface Test Passed
071-00X-XXX
071-01X-XXX
071-02X-XXX
Audio port error
071-03X-XXX
Audio port failure
Chapter 6. Symptom-to-FRU Index
FRU/Action
No action
1. RAID signal cable
2. RAID device
3. RAID adapter card, if installed
4. System board
Information only
Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log
file
1. Make sure the component that
is called out is connected and/or
enabled. See
"Using the Setup
Utility,"
2. Re-run test
3. Replace the component that is
called out in warning statement
4. Replace the component under
test
1. If a component is called out,
make sure it is connected and/or
enabled. See
"Using the Setup
Utility,"
2. Flash the system and re-test. See
"Flash update procedures"
3. Go to
"Undetermined problems"
1. See
"Undetermined problems"
2. Flash the system and re-test. See
"Flash update procedures"
3. Replace component under
function test
No action
1. Run Setup
2. Flash the system. See
update procedures"
3. System board
1. Speakers
2. Microphone
3. Audio card, if installed
4. System board
"Flash


Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents