D15 Camera Manual: Mounting
5. Connect the sensor cable to the lens mount :
Connect the R and L sensor cables with the image
sensors in accordance with the table. Example : In
the case of a D15D-DNight (color/black and white),
the R sensor cable must always be connected to the
lens mount marked with RGB, while the L sensor
cable must always be connected to the lens mount
marked SW.
Never pull the sensor cable forcefully! To remove it, first disconnect the plug by
pressing lightly on the notch (1) and then carefully pull it
upwards (2).
Always avoid direct contact with the contacts on the green
circuit board (ESD) in order to prevent damage arising
now or later and to avoid reducing the service life.
6. Insert the sensor cable : Insert the sensor cable
through the space in the circuit board. Make sure that
the individual wires are gently curved and are not
bent near the plug.
7. Place the lens cover on the image sensors : Carefully
push the lens covers one after another in the direc-
tion of the gray arrow onto the plug until they click
into place.
8. Align the image sensors and cable guide: Align
the image sensors so that the plugs of the sensor
cable point towards the interior of the dome (see red
marking in the figure). This will ensure the images
appear in the correct position later on and not upside
down. Make sure that the sensor cable is as straight
as possible and fix the cable in place using the cor-
responding guides.
© MOBOTIX AG • Security-Vision-Systems • Made in Germany