Specifications - Mira Elite ST Installation Manual

Electric showers 9.8, 10.8 kw
Hide thumbs Also See for Elite ST:
Table of Contents

Advertisement

1. Plumbing
1.1 The 15 mm inlet compression connector incorporates an inlet filter. The inlet
swivels to allow top, bottom or rear entry.
Note! Whilst bottom entry is possible it is not recommended as it may encourage
airlocks.
1.2 The outlet terminates with a 1/2" BSP male thread for connection to a Mira
flexible shower hose.
2. Electrical
This is a high power unit, it is essential to contact your electricity supply company
to make sure that the electricity supply is adequate for the purpose.
2.1 The terminal block will not accept cable larger than 16 mm
The minimum required supply cable size must conform to BS 7671.
2.2 The motor is fitted with a self resetting thermal trip protection device, designed
to operate if the ambient temperatures become too high. The maximum
recommended ambient temperature for the Elite ST is 30°C.
2.3 The following power ratings for the heater tanks are available with their
respective voltages:
Mira Elite ST 9.8 kW @ 240 V / 45 Amps (9.0 kW @ 230 V / 40 Amps).
Mira Elite ST 10.8 kW @ 240 V / 45 Amps (9.9 kW @ 230 V / 45 Amps).
2.4 The motor will absorb approximately 100 Watts maximum power under normal
working conditions.
2.5 The Mira Elite ST is suitable for installation within zone 1 and is rated IP X4.
3. Standards and Approvals
3.1 This Mira Elite ST complies with all relevant directives for CE marking.
Dimensions
Height
Width
Depth

SPECIFICATIONS

6
.
2
340 mm
266 mm
95 mm

Hide quick links: