Fault Diagnosis - Mira Elite ST Installation Manual

Electric showers 9.8, 10.8 kw
Hide thumbs Also See for Elite ST:
Table of Contents

Advertisement

The trouble shooting information below gives details on probable causes and
remedies should difficulties be encountered whilst the shower is in operation.
Warning! There are no user serviceable components beneath the cover of the
shower. Only a competent tradesperson should remove the front cover!
Power
Symptom
Light
Elite ST fails to
OFF
operate.
OFF
ON
No water or very
low flow rate.
ON
Shower cycles
ON
from hot to cold.
ON
Unable to select
ON
a cool enough
temperature.
ON
No water and
ON
motor tone
increases.
ON
OFF
Handset
dripping.
ON
Water will not
turn off.

FAULT DIAGNOSIS

Heater
Low
Setting
Flow
Low / Med /
Light
High
OFF
Any
OFF
Any
ON
ANY
ON
ANY
OFF
MED / HIGH
MED / HIGH
ON
OFF
HIGH
ON
MED / HIGH
ON
ANY
ON
ANY
OFF
ANY
OFF
MED/HIGH
Probable Cause
Electrical supply isolated at
double pole switch.
Fuse blown or MCB/RCD
tripped indicating possible
electrical fault.
Hose or handset sprayplate
blocked.
I n c o m i n g w a t e r s u p p l y
isolating valve turned down
or off.
Temperature knob or heater
setting too high.
Handset sprayplate blocked.
Due to a rise in the stored
water temperature, the power
rating may be too high.
Handset sprayplate blocked.
Cistern has run out of water.
Internal pump unit faulty or
thermal trip has operated.
Flow Valve faulty
Flow Valve, Solenoid or Start/
Stop switch faulty
19
Possible Remedy
Switch on electrical supply
via pullcord or wall mounted
switch.
Renew the fuse or reset the
MCB/RCD. If fault persists,
contact your installer.
Remove and clean.
Turn isolating valve to fully
on position.
Tu r n t h e TO P k n o b t o
M E D I U M s e t t i n g a n d
re-adjust temperature knob
until suitable temperature is
achieved.
Remove and clean.
Tu r n t h e TO P k n o b t o
M E D I U M s e t t i n g a n d
re-adjust temperature knob
until suitable temperature is
achieved.
Remove Handset and clean.
Tu r n o f f t h e E l i t e S T
immediately and resolve
cistern storage difficulty.
Wait for internal pump /
shower to cool down. If still
faulty contact your installer.
Replace
Replace parts as required.