Before carrying out the commissioning procedure install the Shower Fittings,
refer to the Shower Fittings Installation and User Guide.
If you are unsure how an electric shower works, please read through the User
Instructions section before continuing.
1.
Electrical supply is turned
off at the mains.
4.
Check for water leaks.
7.
Push START button.
COMMISSIONING
2.
Turn BOTTOM control to
full cold.
5.
Tu r n TO P c o n t r o l t o
LOW.
8.
0-5 secs
Water will be at full force and
at a cool temperature.
15
3.
Turn water supply fully
on.
6.
S w i t c h o n e l e c t r i c a l
supply.
9.
Turn BOTTOM control
s l o w l y. Te m p e r a t u r e
remains cool and flow is
reduced.