Installation And Removal Of Module - Mitsubishi Electric Q172DCPU User Manual

Motion controller q series
Hide thumbs Also See for Q172DCPU:
Table of Contents

Advertisement

4 INSTALLATION AND WIRING

4.1.3 Installation and removal of module

Securely insert the module
fixing protection into the
module fixing hole so that the
latch is not misaligned.
Using the module fixing hole
as a fulcrum, push the module
in the direction of arrow to
install it into the base unit.
Make sure that the module is
installed in the base unit
securely.
When using module in a place
where there is large vibration
or impact, install them by the
unit fixing screws.
END
This section explains how to install and remove a power supply module, PLC CPU
module, Motion CPU module, Motion module, I/O module, intelligent function module
or another module to and from the base unit.
(1) Installation and removal of the module from Q3 DB,Q6 B
(a) Installation of the module on Q3 B and Q6 B
Base unit
Module
connector
Module
fixing hook
Module fixing hole
Module
fixing hook
Module fixing hole
(Note)
Base unit
Unit fixing
projection
Module
Module
loading
lever
(Note): Screw the Motion CPU module to the main base unit.
4 - 6
Base unit
Module loading
lever
Module
fixing hook
Module fixing hole
Base unit
Module
fixing hook
Module fixing hole