Item
Operating ambient temperature
Storage ambient temperature
Operating ambient humidity
Storage ambient humidity
Vibration resistance
Shock resistance
Operating ambience
Operating altitude
Mounting location
Overvoltage category
(Note-1)
Pollution level
(Note-2
)
(Note-1) : This indicates the section of the power supply to which the equipment is assumed to be connected between the
public electrical power distribution network and the machinery within premises.
Category
applies to equipment for which electrical power is supplied from fixed facilities.
The surge voltage withstand level for up to the rated voltage of 300V is 2500V.
(Note-2) : This index indicates the degree to which conductive material is generated in terms of the environment in which
the equipment is used.
Pollution level 2 is when only non-conductive pollution occurs. A temporary conductivity caused by condensing
must be expected occasionally.
(Note-3) : Do not use or store the Motion controller under pressure higher than the atmospheric pressure of altitude 0m.
Doing so can cause an operation failure.
The Motion controller must be stored and used under the conditions listed in the table of
specifications above.
When not using the module for a long time, disconnect the power line from the Motion controller
or servo amplifier.
Place the Motion controller and servo amplifier in static electricity preventing vinyl bags and store.
When storing for a long time, please contact with our sales representative.
Also, execute a trial operation.
General specifications of Q173DCPU/Q172DCPU module are shown below.
Under intermittent
vibration
Under continuous
vibration
Specification
0 to 55°C (32 to 131°F)
-25 to 75°C (-13 to 167°F)
5 to 95% RH
non-condensing
,
5 to 95% RH
non-condensing
,
Frequency
Acceleration
10 to 57Hz
57 to 150Hz
9.8m/s
10 to 57Hz
57 to 150Hz
4.9m/s
2
147m/s
, 3 times in each of 3 directions X, Y, Z
No corrosive gases
2000m(6561.68ft.) or less
Inside control panel
II or less
2 or less
CAUTION
2 - 18
(Note-3)
Amplitude
0.075mm
——
(0.003inch)
2
——
0.035mm
——
(0.001inch)
2
——
Sweep count
10 times each
in X, Y, Z
directions
(For 80 min.)