4 INSTALLATION AND WIRING

4.1.2 Instructions for mounting the base unit

OUT
Ws
1
Q38DB
W
328 (12.91)
Ws
1
170 ± 0.3
Ws
2
(6.69 ± 0.01)
138 ± 0.3
Ws
3
(5.43 ± 0.01)
H
Hs
1
Hs
2
When mounting the Motion controller to an enclosure or similar, fully consider its
operability, maintainability and environmental resistance.
(1) Fitting dimensions
Fitting dimensions of each base unit are as follows:
5-fixing screw (M4 14)
5V
SG
CPU
I/O0
POWER
I/O1
FG
Ws
2
Q312DB
439 (17.28)
189 (7.44)
170 ± 0.3
(6.69 ± 0.01)
167 ± 0.3
(6.57 ± 0.01)
249 ± 0.3
(9.80 ± 0.01)
I/O5
I/O2
I/O3
I/O4
W
Q63B
Q65B
245 (9.65)
15.5 (0.61)
222.5 ± 0.3
(8.76 ± 0.01)
98 (3.86)
7 (0.28)
80 ± 0.3 (3.15 ± 0.01)
4 - 3
I/O7
I/O8
I/O9
I/O6
I/O10
Ws
3
Q68B
328 (12.91)
190 ± 0.3
(7.48 ± 0.01)
116 ± 0.3
(4.57 ± 0.01)
I/O11
I / O11
Q312DB
Q612B
439 (17.28)
190 ± 0.3
(7.48 ± 0.01)
227 ± 0.3
(8.93 ± 0.01)
[Unit: mm (inch)]