Asynchronous Operation Pane - HP xp12000 User Manual

Continuous access xp
Hide thumbs Also See for xp12000:
Table of Contents

Advertisement

When the speed mode is standard, two port numbers are displayed in a row, and the speed mode can
be modified on a two- port basis.
When the speed mode is high, the port number is displayed on a package basis, and the speed mode
can be modified on a package basis.
Attribute: Port type (Initiator, Target, RCU Target, External, RCP, or LCP).
PCB Mode: Speed mode of the port (only for the fibre packages): standard, high-speed, or high-speed
(2 port).
CU: Range of CU images (00-0F or 10-1F), which is displayed only for serial ports.
In the Port tree, port type can be selected to display specified information in the Port list. For example,
when Initiator is selected in the Port tree, the system looks for ports of Initiator from all ports entered, and
lists Initiator ports in the Port list. Only one port type can be selected in the tree.

Asynchronous Operation pane

The Asynchronous Operation pane displays consistency group information for the connected disk array
and provides access to the Continuous Access XP Asynchronous pair operation (see
XP Asynchronous
The Asynchronous Operation pane is updated when the tab is switched from one to another, Refresh is
clicked, and settings are applied.
Figure 21
Asynchronous Operation pane
The Asynchronous Operation pane contains the following items:
Consistency Group tree: All consistency groups (default), only consistency groups already in use
(Used), or consistency groups available for use (Not Used).
Consistency Group list: Consists of the following items:
• CTG: Consistency group number.
• This CU: CU that initially registered the consistency group. When the consistency group is not
registered, the column is blank.
• MCU: The local CU registered the consistency group.
• RCU: The consistency group is registered from the paired CU (the local CU is RCU).
• M&R: MCU and RCU are in the same disk array.
• M-R Path: Fibre Channel or serial. When the consistency group is not registered, the column is
blank.
operations" on page 77).
Continuous Access XP user guide for the XP12000/XP10000
"Continuous Access
57