Volume Icons For Continuous Access Xp Operations; Status Icons For Continuous Access Xp Operations - HP xp12000 User Manual

Continuous access xp
Hide thumbs Also See for xp12000:
Table of Contents

Advertisement

NOTE:
To change the number of items that can be displayed without scrolling, change the font size.
Figure 16
Volume list (partial view)
Volume icon: Status of volumes. Table 19 shows the icons.
Table 19

Volume icons for Continuous Access XP operations

Icon
Explanation
SMPL
P-VOL
S-VOL
Port, G-ID, and LUN: Port number, group number (G-ID), LU host group number and name, and LU
number (LUN).
NOTE:
If # is added to the end of an LDEV number, such as 00:3C#, the LDEV is an external
volume. For details about external volumes, see the HP StorageWorks External Storage XP user
guide.
Status: See
"Continuous Access XP volume pair
Continuous Access XP pair status. Table 20 shows the icons.
Table 20

Status icons for Continuous Access XP operations

Icon
Explanation
SMPL. Volume is not currently assigned to a
operation starts the initial copy, the volume status changes to COPY.
Continuous Access XP
COPY.
identical. When the initial copy is complete, the status changes to PAIR.
PAIR. Volume is currently assigned to a
synchronized. All updates from the host to the P-VOL are duplicated at the S-VOL.
PSUE. Pair was suspended by the MCU or RCU due to an error condition. Volumes in this pair are not
synchronized.
PSUS. Pair was split by the user (pairsplit-r), or pair was deleted by the user from the RCU (pairsplit-S).
Volumes in this pair are not synchronized.
Continuous Access XP
PDUB.
Continuous Access XP
the
status" on page 25 for further information about
Continuous Access XP
initial copy operation is in progress. Data on the pair is not fully
Continuous Access XP
LUSE pair is in the COPY or PAIR state, but at least one LDEV pair within
LUSE pair is in the SMPL or PSUE state.
Continuous Access XP user guide for the XP12000/XP10000
pair. When the paircreate
pair, and the pair is 100%