SMA Solar Technology AG
The additionally required PV generation data will be determined either directly by the connected
SMA inverters or can be captured via an additional PV production meter in PV systems with
Sunny Home Manager. If a DC-coupled storage system is used (e.g. Sunny Boy Smart Energy), you
must not use a PV production meter. Instead, the PV generation data must always be read out
directly from the device, otherwise no differentiation between direct consumption and battery
charging or discharging will be possible.
Delayed display of data due to incompatible energy meter
When using incompatible energy meters, there may be a delay in the data being displayed in
the Current tab.
• Use energy meters recommended by SMA (see planning guidelines "SMA Smart Home"
at www.SMA-Solar.com).
Display with Battery
If a battery inverter is present in your system, you can select between the simplified view without
battery data and the detailed view with battery data.
• To display the data of the battery in the diagram and in the area Energy balance, activate
the checkbox Detailed view.
• To avoid displaying the data of the battery in the diagram and in the area Energy Balance,
deactivate the checkbox Detailed view.
Showing and Hiding Diagram Data
You can show and hide the diagram data indicated in the legend by clicking on the respective
entry in the legend.