Miele@Home Devices / Devices With Communication Via Data Exchange Protocol - SMA sunny home manager User Manual

Hide thumbs Also See for sunny home manager:
Table of Contents

Advertisement

SMA Solar Technology AG
15.5 Miele@home Devices / Devices with Communication
via Data Exchange Protocol
Problem
Message in the system log-
book:
EM gateway not found:
SEMP, name:
or
EM gateway not found:
Miele@home, name:
User Manual
Cause and corrective measure
The gateway is not connected to the local network.
Corrective measures:
• Check whether all network cable plugs are inserted and
locked.
The voltage supply of the gateway is faulty.
Corrective measures:
• Check whether the power plug of the gateway is plugged into
the outlet.
The gateway could not be found by the Sunny Home Manager.
Corrective measures:
• Restart the gateway (see manual of the gateway).
The Sunny Home Manager and the gateway are located in different
local networks.
Corrective measures:
• Connect the gateway and the Sunny Home Manager to the
same network switch/router.
The Sunny Home Manager and the gateway are configured for dif-
ferent IP subnets.
Corrective measures:
• If your router supports DHCP, configure the
Sunny Home Manager (default setting) and the gateway to
DHCP (see manual of the gateway).
• If your router does not support DHCP, manually assign IP
addresses in the same subnet for the Sunny Home Manager
and the gateway (see manual of the respective device).
The voltage supply of the device is faulty.
Corrective measures:
• Check whether the power plug of the device is plugged into
the outlet.
15 Troubleshooting