Command Function
Front Panel Lock (Executive) Modes
NOTE:
See
Locking and Unlocking the Front Panel (Executive Mode)
Lock all front panel functions
Lock advanced front panel functions
Unlock all front panel functions
View lock status (executive mode)
EDID (Extended Display Identification Data) Commands
Assign EDID data to an input
Assign EDID data to all inputs
Save output EDID
NOTE:
User-assigned EDID files = 26–33 for DXP 44, 84, and 88, 34–49 for DXP 168 and 1616.
View EDID input data assignment
X@
NOTE:
=
Input number
X#
=
Output number
X1(
=
EDID file reference number
X2%
=
Front panel Lock mode status
(executive mode)
ASCII Command
Response
(Host to Switcher)
(Switcher to Host)
1X
Exe1
2X
Exe2
0X
Exe0
X2%]
X
E
X@
X1(
}
A
*
EDID
EdidA
E
X1(
}
A
*EDID
EdidA00*
E
X#
X1(
}
S
EDID
EdidS
*
E
X@
}
X1(]
A
EDID
1 – maximum number of inputs for your model
1 – maximum number of outputs for your model
See the
Default = 9 (720p @ 60 Hz)
0 = lock mode 0 (unlocked), 1 = lock mode 1, 2 = lock mode 2
Additional Description
on page 22 for more information on the lock modes.
]
Enable lock mode 1.
]
Enable lock mode
]
Enable lock mode 0.
Display current lock mode
X@
X1(]
*
Assign EDID file
X1(]
Assign EDID information files to all
inputs. See the
beginning on page 32, for a list of values
contained in each EDID file.
X#
X1(]
Store the EDID of output
*
user-assigned EDID file
View number of EDID file assigned to
X@
input
EDID Reference
Tables, beginning on page 32.
.
2
X2%
.
X1(
X@
to input
.
EDID Reference
Tables,
X#
as
X1(
.
.

Advertisement