2.2

Pull Type

2.2.1
Control Module on Tractor (Non-ISOBUS Ready Tractor)
1. Securely mount the control module (E01) inside the tractor cab.
2. Tee the CANbus interface cable (C40) between Trimble cable 75834 and Trimble cable
77368.
3. Connect the 6 pin Deutsch plug on cable C40 to the end of the control module with only
one Deutsch connector.
4. Connect cable C41 to the CANbus connector and route the cable to the hitch of the
tractor. Connect the two-way coupler (E12) to the end of cable C41.
5. Connect cable C01 to the coupler (E12) and route towards the rear of the sprayer. The
two-way coupler (E12) will provide the hitch disconnect.
Figure 2: Pull Type with Control Module on Non-ISOBUS Ready Tractor Installation