Norac UC5 Installation Manual

Spray height controller
Hide thumbs Also See for UC5:

Advertisement

Spray Height Controller
Hardi Aftermarket
Installation Manual
HD07

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UC5 and is the answer not in the manual?

Questions and answers

Summary of Contents for Norac UC5

  • Page 1 Spray Height Controller Hardi Aftermarket Installation Manual HD07...
  • Page 2 Reorder P/N: UC5-BC-HD07-INST Rev B (Hardi Aftermarket) NOTICE: NORAC Systems International Inc. reserves the right to improve products and their specifications without notice and without the requirement to update products sold previously. Every effort has been made to ensure the accuracy of the information...
  • Page 3: Table Of Contents

    Contents Introduction .....................1 General UC5 System Layout .................2 Kit Parts ......................3 Pre-Install Checklist ..................9 Ultrasonic Sensor Installation ..............10 Roll Sensor Installation ................15 Module Installation ..................19 Connecting the Sensors to the CANbus ........... 23 Hydraulic Installation .................. 24 Software Setup .....................
  • Page 4: Introduction

    1 Introduction Congratulations on your purchase of the NORAC UC5 Spray Height Controller. This system is manufactured with top quality components and is engineered using the latest technology to provide operating reliability unmatched for years to come. When properly used the system can provide protection from sprayer boom damage, improve sprayer efficiency, and ensure chemicals are applied correctly.
  • Page 5: General Uc5 System Layout

    2 General UC5 System Layout Figure 1 illustrates the general layout of the UC5 system components: Figure 1: General UC5 System Layout...
  • Page 6: Kit Parts

    3 Kit Parts Kit Overview Figure 2: HD03 System Parts...
  • Page 7 Hydraulic Plumbing Figure 3: HD03 Hydraulic Plumbing: Single Acting (Force Boom)
  • Page 8 Figure 4: HD03 Hydraulic Plumbing: Double Acting (Eagle Boom)
  • Page 9 CABLE UC5 NETWORK 18 AWG 20M 43230-04 CABLE UC5 VALVE 2PIN DT TO 2PIN DT 43240-08 CABLE UC5 INTERFACE TILT AMP (SUPERSEAL) 43240-09 CABLE UC5 INTERFACE MAIN AMP (SUPERSEAL 240" W/ BYPASS) 43250-06 CABLE UC5 BATTERY PIGTAIL FUSED 43710 UC5 CONTROLLER MODULE 43720...
  • Page 10 P - PIPE The 6MBP plugs (F03) are only used for the single acting plumbing installation. The use of dielectric grease is not recommended on any NORAC electrical connections. To ensure all stainless steel hardware does not gall or seize apply a light coating of the supplied Permatex Anti-seize grease to all threaded parts upon installation.
  • Page 11 Optional Pressure and Tank Hose Kit (P/N: 44865-49) If you require a separate pressure and tank line from your tractor to your NORAC valve block, you can order the hoses and fittings as a kit (P/N: 44865-49). Part Number Name...
  • Page 12: Pre-Install Checklist

    4 Pre-Install Checklist The pre-install checklist is necessary to check the existing sprayer functionality before the installation. 1. Unfold the sprayer over a flat, unobstructed area (i.e. no power lines…etc.). 2. Ensure all boom-fold operations are functional (place a check mark in boxes below). 3.
  • Page 13: Ultrasonic Sensor Installation

    5 Ultrasonic Sensor Installation Bracket Assembly Assemble the breakaway sensor bracket as illustrated in Figure 6, following the instructions below. Figure 6: Breakaway Bracket Assembly 1. Compress the spring and insert it together with the collar into the base. 2. Slide the tube through the assembled part. 3.
  • Page 14 Ultrasonic Sensor Serial Number Arrangement When installing the UC5 sensors, start with the smallest serial number on the left-hand side, and proceed to the largest serial number on the right hand side. Each UC5 sensor has a serial number stamped on the sensor housing.
  • Page 15 Ultrasonic Sensor Mounting Guidelines The following guidelines will ensure optimal sensor performance and prevent sensor measurement error. These rules should be followed for both the wing sensors and the main lift (middle) sensor. 1. In its lowest position, the sensor must be 9 inches (23 cm) or more from the ground (A). 2.
  • Page 16 If the sensor is mounted to this portion of the boom, the system will force the boom downwards towards the ground as the boom folds backwards. 4. Mount the NORAC UC5 ultrasonic sensor into the sensor bracket and run the sensor cable through the sensor tube.
  • Page 17 Main Lift Sensor Installation Figure 10: Main Lift Bracket Assembly 1. There are a variety of ways to mount the main lift bracket on most sprayers. The bracket should position the sensor approximately in the center of the sprayer, forward of the boom.
  • Page 18: Roll Sensor Installation

    6 Roll Sensor Installation Bracket Assembly 1. Securely mount the roll sensors to the included roll sensor brackets using the #6 machine screw and nylon lock-nuts. 2. The orientation of the mounted roll sensor to the roll sensor bracket will depend on the bracket mounting.
  • Page 19 Roll Sensor Mounting Guidelines: Trapeze-Suspended Booms 1. When mounting the roll sensors, mount one to the trapeze link (boom frame) and one to the trapeze support (chassis). For optimal performance, minimize the distance from the boom frame roll sensor to the pivot point (A) and minimize the vertical distance between the chassis roll sensor and the pivot point (B).
  • Page 20 Roll Sensor Mounting on a Twin Force / Force FTZ Boom Figure 15: Boom Frame Roll Sensor Mounting (Viewed from the rear of sprayer) Figure 16: Chassis Roll Sensor Mounting (Viewed from the front of sprayer)
  • Page 21 Roll Sensor Mounting on an Eagle Boom Figure 17: Roll Sensor Mounting (Viewed from the rear of sprayer)
  • Page 22: Module Installation

    7 Module Installation An optional module mounting bracket kit is available for purchase from NORAC. mounting brackets are compatible with control modules and input modules. One kit is needed per module. Item Part Number Name Quantity 43708 UC5 MOUNTING BRACKET KIT (CONTROL AND INPUT MODULES) Control Module 1.
  • Page 23 Valve Module 1. Install the valve module (E02) to the top of the NORAC valve block. Orient the 6-pin Deutsch (CANbus) connectors towards the P and T ports with the label facing up. Output Number Normal Function Left Up Left Down...
  • Page 24 Figure 21: Valve Module Bracket Installation 5. Connect the valve module CANbus to cable C01 from the control module. Route cable C02 from the other CANbus connector to the input module. 6. With the valve module securely mounted to the valve block, connect the valve cables (C10), to the valve coils.
  • Page 25 Input Module 1. Install the input module (E03) on the boom near the Hardi valve block. Secure it to the boom using cable ties or optional brackets 2. Connect the free end of the CANbus cable (C02) from the valve module to the input module.
  • Page 26: Connecting The Sensors To The Canbus

    Follow existing cables and hoses to be sure the cable will not be pinched or stretched. Figure 24: UC5 Module Locations and Cable Connections 5. At the sensor brackets, attach a 2-way coupler with terminator (E20) to the sprayer boom.
  • Page 27: Hydraulic Installation

    Valve Assembly: Single Acting 1. On a clean surface remove the plastic plugs from the block. 2. Install two 6MB 6MJ (F02) fittings into the P and T ports on the NORAC block. Tighten to 18 ft-lbs (24 Nm). 3. Insert the two orifices (F01) into the “B” ports with the notch facing out.
  • Page 28 Valve Assembly: Double Acting 1. On a clean surface remove the plastic plugs from the block. 2. Install two 3/8” x 1/4” BSPP (HD01) fittings into the P and T ports on the NORAC block. Tighten to 18 ft-lbs (24 Nm).
  • Page 29 Valve Block Mounting 1. A suitable mounting location for the valve block is illustrated in Figure 27. 2. Insert the threaded rod into the block and use a hex nut to hold the rod. The block holes are 3/8” NC-1” deep. If bolts are used instead of the threaded rod, ensure the bolts thread in at least 3/8”.
  • Page 30 Figure 3. 2. Install the 90 degree fittings on hoses H03 onto the “B” ports on the NORAC valve block. 3. Route the free ends of the hoses to each of the wing tilt cylinders.
  • Page 31 Figure 4. 2. Install the 90 degree fittings on hoses H03 onto the “A” ports on the NORAC valve block. 3. Install the 90 degree fittings on hoses H02 onto the “A” and “B” ports on the NORAC valve block.
  • Page 32: Software Setup

    Begin the AUTOMATIC SYSTEM SETUP procedure as described in the UC5 Spray Height Control Operator’s Manual. 5. For optimal performance of the UC5 system, there should be very little play at the hitch clevis. The addition of polymer washers can help tighten up this connection (Figure 30).
  • Page 33: Cable Drawings

    11 Cable Drawings 11.1 ITEM C01: 43220-10 - CABLE UC5 NETWORK 14 AWG - 10M 11.2 ITEM C02: 43220-01 - CABLE UC5 NETWORK 14 AWG - 1M...
  • Page 34 11.3 ITEM C03: 43210-03 - CABLE UC5 NETWORK 18 AWG - 3M 11.4 ITEM C04: 43210-01 - CABLE UC5 NETWORK 18 AWG - 1M...
  • Page 35 11.5 ITEM C05: 43210-20 - CABLE UC5 NETWORK 18 AWG - 20M 11.6 ITEM C10: 43230-04 – CABLE UC5 VALVE DT TO DT...
  • Page 36 11.7 ITEM C20: 43240-08 – CABLE UC5 INTERFACE TILT AMP (SUPERSEAL)
  • Page 37 11.8 ITEM C21: 43240-09 – CABLE UC5 INTERFACE MAIN AMP (SUPERSEAL 240” WITH BYPASS)
  • Page 38 11.9 ITEM C30: 43250-06 – CABLE UC5 BATTERY PIGTAIL FUSED...
  • Page 39 Canada NORAC Systems International Inc. Phone: (+1) 306 664 6711 Toll Free: 1 800 667 3921 Shipping Address: 3702 Kinnear Place Saskatoon, SK S7P 0A6 United States NORAC, Inc. Phone: (+1) 952 224 4142 Toll Free: 1 866 306 6722...

Table of Contents