10. Switch Housing Assembly.

Remove 3 screws from outer edge of switch housing
plate (save screws for later use).
Remove 1 screw from fitter plate (on underside of
motor) and partially loosen the other 2 screws. Align
slotted holes in middle of switch housing plate with
loosened screws in fitter plate, allowing male plug from
motor housing to come through large hole in middle of
switch housing plate. Twist switch housing plate to lock.
Re-insert screw that was just removed and tighten all 3
screws securely.
Connect male plug from motor housing to female plug
from switch housing. Make sure plugs connect tightly.
Align holes in switch housing with holes in switch
housing plate. Re-insert screws that were previously
removed and securely tighten all 3 screws with a Phillips
screwdriver.

11. Testing Your Fan.

It is recommended that you test fan before
finalizing installation. Restore power from circuit
box and wall switch (if applicable). Test fan speeds
with pull chain. Start at the OFF position (no blade
movement). First pull will set the fan to HI. Second
pull will set the fan to MEDIUM. Third pull will set
the fan to LOW. Fourth pull will re-set the fan to
OFF setting. (diagram 1) If fan does not function,
please refer to "Troubleshooting" section to solve
any issues before contacting Customer Service.
Turn fan completely off before moving the reverse
switch (located on switch housing). Set reverse
switch to recirculate air depending on the season:
- LEFT position in summer (diagram 2)
- RIGHT position in winter (diagram 3)
A ceiling fan will allow you to raise your
thermostat setting in summer and lower your
thermostat setting in winter without feeling a
difference in your comfort.
Important: Reverse switch must be set either
completely to the LEFT or completely to the RIGHT
for fan to function. If the reverse switch is set in
the middle position (diagram 4), fan will not
operate.
Attach pull chain extension supplied or custom
pull chain extension (sold separately) to end of the
pull chain.
switch housing
plate
motor housing
switch
housing
reverse
switch
diagram 1
diagram 2
page 8
motor housing
fitter plate
male plug
female plug
switch housing
pull chain
extension