Adaptive Function; Sensor Setting - Pentair NRG-DM Instructions Manual

Software version 1.60
Hide thumbs Also See for NRG-DM:
Table of Contents

Advertisement

performed after this automatic calibration and only in the
few cases where the automatic calibration seems not to be
100% accurate.

7.3.2 ADAPTIVE FUNCTION

Thanks to the adaptive function, the NRG-DM will know
when to switch your heating on, in order to obtain the
desired temperature at the desired time. The Adaptive
function is only active in the Event Mode and is activated
from factory. You can de-activate the Adaptive function in
the Adaptive function menu.
The Adaptive function will optimize the energy consumption
to the desired comfort of the user.

7.3.3 SENSOR SETTING

The NRG-DM can operate in different sensor settings.
Some of the settings are activated in the thermostat when a
physical floor sensor is installed; others are activated when
there is no external sensor installed.
• When there is a floor sensor installed and connected
• Floor
The NRG-DM is regulating the temperature based on
the input given by the floor sensor (embedded in the
floor)
• Room/limit
The NRG-DM is regulating the temperature based
on the input of the room sensor (integrated in the
thermostat) but is making sure the floor is not
exceeding a desired temperature measured by the
floor sensor
• When there is no external sensor installed or connected
• Room
The NRG-DM is regulating the temperature based
on the input of the room sensor (integrated in the
thermostat)
• No sensor
The thermostat works like a regulator. It will work in
duty cycles and it will activate the electrical heating
cables during a percentage of this duty cycle.
15

Advertisement

Table of Contents
loading

Table of Contents