Path Operation List (When Product Name Is Clicked) - HP StorageWorks XP24000 User Manual

External storage
Hide thumbs Also See for StorageWorks XP24000:
Table of Contents

Advertisement

Item
FLI_TOV
Margin
Status
Pop-up menu
Table 9 Status of the Cross-subsystem Path Displayed in the Status
Displayed Item
Normal
-
Unknown
Blockade
Disconnect
Warning
Checking

Path Operation List (When Product Name is Clicked)

When you click a product name in the Path Operation tree, the WWN indicating the port in the
external storage system appears in the list on the right.
56
Using the XP External Storage GUI
Description
The wait time (in seconds) from the switch to FLOGI when
the switch is connected. This value is automatically set by
XP External Storage. You cannot change the value.
The additional wait time (in seconds) to FLI_TOV (FLOGI
wait time) or PLI_TOV (PLOGI wait time). This value is
automatically set by XP External Storage. You cannot
change the value. As a result, the sum of FLI_TOV time and
the margin time, or the sum of PLI_TOV time and the margin
time is set as a total wait time.
Status of the cross-subsystem path.
the displayed statuses.
Right-click a row in the list to perform the operations:
Disconnect Paths: Allows you to stop the use of the
cross-subsystem paths that are connected to the selected
external port of the local storage system. See
the Use of Paths to the External Volume (Disconnect
Paths)" (page
90).
Check Paths: Allows you to resume using the
cross-subsystem paths that are connected to the selected
external port of the local storage system. See
the Paths to the External Volume (Check Paths)"
(page
91).
Description
The cross-subsystem path is normal.
The status of the cross-subsystem path is not retrieved yet.
Click Status in the Path Operation window to change the
name of the button to Status: Enable, and display the status
of the cross-subsystem path.
The status of the cross-subsystem path is unknown.
The cross-subsystem path is blocked.
Connecting to the external storage system or the external
volume is intentionally stopped using the Disconnect
Subsystem command or the Disconnect Volume command.
There are cross-subsystem paths whose status is not normal.
Check the status of the cross-subsystem paths.
The processing of checking the cross-subsystem path status
is in progress.
Table 9 (page 56)
shows
"Stopping
"Restoring