Preview Dialog Box - HP StorageWorks XP24000 User Manual

External storage
Hide thumbs Also See for StorageWorks XP24000:
Table of Contents

Advertisement

Item
Pop-up menu
The Cross-system Paths list provides the following information:
Table 7 Cross-subsystem Paths List Details
Item
Priority
Port
WWN
Pop-up menu

Preview Dialog Box

Use the Preview dialog box to check or cancel the settings that will be applied to the local storage
system. To display the Preview dialog box, click Preview in the Volume Operation window, the
HP Confidential
Description
For details about Characteristic2, see
Storage Systems" (page
129).
Right-click a row in the External Volumes list (at the top of
the window) to perform the following operations:
Mapping Path Information: Opens the Mapping Path
Information dialog box. This dialog box allows you to
see the list of the mapping paths set to the selected
external volume. See
"Checking the External Volume
Details" (page
81).
LDEV Information: Opens the LDEV Information dialog
box. This dialog box allows you to see the emulation
type and the capacity of the selected external volume.
See
"Checking the External Volume Details" (page
Delete Volume: Cancels the mapping of the selected
external volume. See
"Deleting the External Volume
Mapping (Delete Volume Command)" (page
Disconnect Volume: Disconnects the selected external
volume. See
"Disconnecting an Individual External
Volume (Disconnect Volume Operation)" (page
Check Paths & Restore Volume: Reconnects the selected
external volume. See
"Checking Connection Status and
Resuming External Volume Operation" (page
Change Cache Mode: Changes the cache mode set to
the selected external volume. See
Mode Setting of the External Volume" (page
Inflow Control: Allows you to select whether to stop
writing to the cache memory when it is impossible to
write to the selected external volume. See
the Inflow Control Setting of the External Volume"
(page
92).
Description
Priority of the cross-subsystem paths, where 1 indicates the
cross-subsystem path with the highest priority.
The port number in the local storage system connecting to
the external storage system.
Identification number of the port in the external storage
system.
Right-click a row in the Cross-subsystem Paths list (at the
bottom of the window) to perform the following operation:
Configure Cross-Subsystem Paths: Opens the Configure
Cross-subsystem Paths dialog box. This dialog box
allows you to add and delete cross-subsystem paths,
and also change the priority of the selected
cross-subsystem path. See
Paths Dialog Box" (page
Volume Operation Window
"Connecting External
81).
95).
88).
89).
"Changing the Cache
91).
"Changing
"Configure Cross-subsystem
75).
51

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks xp20000

Table of Contents