Table 58 Serial number display (IBM XIV Series) (continued)
Display in USP V/VM
The last 5 digits of Serial
Number
Characteristic 1

Fujitsu FibreCAT CX Series

System Option mode
When you connect a Fujitsu FibreCAT CX series as an external storage system, set system option
mode 725 of the local storage system. If system option mode 725 is not set, the external storage
system might be blocked when performing maintenance, including rebooting the controller of the
external storage system by the firmware update and so on. For instructions about setting system
option mode 725, contact
System Parameter for Connecting Fujitsu FibreCAT CX Series
When you connect a Fujitsu FibreCAT CX series as an external storage system, set the system
parameters of the Fujitsu FibreCAT CX series according to the following table. For the system
parameters that are not in the following table, refer to the documentation of the Fujitsu FibreCAT
CX series and set the parameters appropriately for the connecting configuration.
Table 59 System Parameters for Connecting Fujitsu FibreCAT CX Series
Parameter
Initiator Type
Failover Mode
Notes on Connecting Fujitsu FibreCAT CX Series
Volumes created with the RAID0 level or Individual Disk Units (JBOD disks) of Fujitsu FibreCAT CX
series are not supported.
SGI IS4600 Series
When connecting an SGI IS4600 series as an external storage system, set the system parameters
of the SGI IS4600 series according to the following table. For system parameters that are not in
the following table, refer to the documentation of the SGI IS4600 series and set the parameters
appropriately for the connecting configuration.
Table 60 SGI IS4600 Series
Parameter
host type
Non-HP Storage Systems
Generally, when connecting a non-HP storage system as the external storage system, the non-HP
storage system port must be configured as a target attached to a Windows host. The third-party
vendor should be contacted as necessary for the technical details to accomplish this.
146 Connecting External Storage Systems
Hexadecimal value
Hexadecimal value
Display in IBM XIV
The last 5 digits of (System)
Serial number
Device serial number
Parameter Setting
CLARiiON Open
2
Parameter Setting
When alternate paths are connected to different clusters
on the SGI IS4600 series side: Linux
Decimal value
Decimal value
HP Confidential