Table 38 Path status and examples of recovery procedure (P9500 Disk Array) (continued)
Path Status
Cannot detect port

Notes on Using the Power Savings Option (AMS/WMS)

When the AMS 2500, AMS 2300 or AMS 2100 storage system is connected as an external
storage system and the Power Savings option is enabled on the external storage system, do not
access external volumes from a host if the external volumes are spinning down. If an external
volume is accessed from a host when the external volume is spinning down, the status of the external
volume changes to Blockade.
If the status of the external volume changes to Blockade, the external volume will be automatically
restored in several hours. You can also manually restore the external volumes by using the Check
Paths & Restore Volume command.
Thunder 9500V Storage System
System Parameters
Table 39 (page 133)
on the Thunder 9500V storage system.
Table 39 System Parameters (Thunder 9500V)
Window Names
System Startup Settings
Common 1
HP Confidential
explains whether to specify system parameters when making settings on ports
Parameters
Start Attribute
Single Mode
Dual Active Mode
Hot Stand-By Mode
Delay Planned Shutdown
Examples of Recovery Procedure
volume. If the volume is protected by the access attribute,
release the protection.
There is a problem with connection to the external storage
system. The possible causes are:
The fibre cable is not physically connected in the proper
way.
The setting of the topology does not match between the
external port and the target port.
If the external storage system is connected through
switches, the settings for the switches may not be
appropriate.
Make sure that the fibre cable is connected properly, and
then set the fibre channel port properly using LUN
Manager.
The LUN security may have been enabled by LUN
Manager. Check if the LUN security is enabled or not. If
the LUN security is enabled, disable the LUN security.
Parameter Settings
Specify this parameter when the Thunder
9500V storage system is in the one
controller configuration.
Specify this parameter when the Thunder
9500V storage system is in the two
controller configuration.
NOTE:
Be sure to specify that Data Share
Mode will be used.
Do not specify this parameter.
You can either specify this parameter or
omit specifying this parameter.
Thunder 9500V Storage System 133