Hardware Description
Item Indicator, Button Description
1
POWER LED
(green)
2
READY LED
(green)
3
FAULT LED
(orange)
4
IDENTIFY LED
(blue)
Table 12: DX80 Indicators on the Left Side of the Front Panel (without Front Cover)
Item Indicator, Button Description
1
AutoPWR
2
MODE SEL
3
IP RST
4
Power Switch
Table 13: DX80 Switches on the Left Side of the Front Panel (with Front Cover Removed)
U41842-J-Z125-1-76
Glows green when the power is turned on.
Glows green when device is available for use.
Glows orange when an internal device part abnormality has
been detected.
Blinks orange when a device part which needs preventive
replacement has been detected.
Not used with CS800.
Enables the AC Auto-Link Mode (this function automatically
turns on the linked device once AC power is supplied).
This switch is set to "OFF" as the factory setting.
Enables the device power to be turned on via power linkage.
This switch is set to "ON" as the factory setting and should not
be set to "OFF".
Not used in DX80 expansion modules.
Not used in the DX80 expansion modules.
CS800 Storage Expansion Module