9.4. Preselect mode
In this mode, a single, double or triple dose setting is selected using the configuration
buttons (
). The preselection of a single, double or triple* dose will remain active
until changed by selecting another dose option. The preselection will be illustrated
on the display screen with the corresponding icon (
).
The preselected dose is activated with a single press/tap of the appropriate numeric
LCD icon (
). The display screen (
) will indicate an icon representing either a
single, double or triple dose, along with the programmed time of the dose counting
down from total dose time to zero.
Also, once the dose cycle has been activated, the dosis button (
) can be pressed/
released, to suspend the cycle. If the dose pulse button is pressed/released again,
within 8 seconds, the cycle will continue from the point at which it was suspended. If
more than 8 seconds pass, the dose cycle will start a new, complete dose cycle.
Grind pause can be activated or deactivated by pressing the lower pulse button
(
). First, set up by following these steps: MENU / SET UP SETTINGS / SET UP GRIND
PAUSE.
* (only for models with possibility to offer three doses).
9.5. Instant Mode
In this mode of operation when making the selection of one, two or three* doses of
coffee by pressing the appropriate numeric LCD icon (
) screen starts grinding the
selected dosis without the need to actuate the lower dose button (
).
The time set for that dose will decrease to zero, at which point the dose ends.
Once the cycle starts grinding using the lower dose button (
) and is pressed again,
the grinding cycle will stop. If within 8 seconds it is pressed again, it will complete
the remaining time of the original dose time setting. After 8 seconds of inactivity the
grinder will return to standby mode.
To pause by pressing the lower activation button (
), you can enable or disable,
accessing MENU / SET UP SETTINGS / SET UP GRIND PAUSE.
In this mode, pause grinding may also be performed by pressing the active icon on the
) this pause cannot be enabled or disabled via the MENU.
LCD display (
* (only for models with possibility to offer three doses).
14
ORIGINAL INSTRUCTIONS | Ref. quality process 002/03 | v. 19/07/2016 | K06315

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FRESH ON DEMAND and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

F10 conic od

Table of Contents