Replacement Procedure
1.
If the printer is equipped with smart card, transfer the circuit board standoffs
from the old board to the new board, and replace the smart card interface
board.
2.
If the printer is equipped with magnetic stripe, replace the magnetic stripe
board.
3.
Reconnect all cables to the board. Refer to the
on page 6-31 for details.
4.
Reassemble the printer.
Restore the Printer Values
1.
Using Notepad, open the original configuration script you saved in step 3 on
page 6-32.
2.
Locate the entry Ribbon Type:xx, and delete the whole line.
3.
Resave the file.
4.
Plug the printer in, turn it on, and open the Diagnostic software.
5.
From the Printer menu select Configuration Script.
6.
Click on the Load Configuration Script button and select the configuration
file.
7.
Click on the Run All button.
8.
Click on the Save to Power-on Defaults button.
6-34
Before running the script, verify that the Printer ID in the script file
matches the serial number on the printer.