6.
Remove the two screws that secure the pick motor to the transport chassis,
and remove the motor.
Replacement Procedure
1.
Place the pick roller in the transport chassis.
2.
While positioning the pick motor, rotate the pick roller until the shaft-flat
lines up with the flat on the roller.
3.
Tighten the mounting screws to 8 in-lbs.
4.
Reconnect the wires to the motor. (The motor will turn backward if the wires
are reversed.)
5.
Continue reassembling the printer.
6.
Run the Pick and Eject Card Test in Diagnostics to verify that the motor is
functioning properly.