Philips KV-S5055C Service Manual page 94

High speed color scanner
Table of Contents

Advertisement

9.3.5.
Scanner Condition
Item
Sleep Mode
1. Click "Sleep Mode" on the main menu (Service Utility).
2. Set "Waiting Time" (Unit: minutes) to specify the amount of
time until the scanner enters the sleep mode.
3. Click "OK" to renew the setting.
Clean Imprinter
1. Click "Clean Imprinter" on the main menu to clean the
imprinter's print head.
Buzzer Setting
1. Click "Buzzer Setting" on the main menu.
2. Set "Buzzer Setting (ON or OFF)" on the "Buzzer Setting"
dialog box.
3. Click "OK" to renew the setting.
User Shading
1. Click "User Shading" on the main menu.
2. Push "Start Shading" or "Restore Default" on the "User
Shading" dialog box.
Note:
a. When selecting "Restore Default", the factory-setting
b. The following procedures "3" or more are available
3. Clean the conveyor, rollers, Scanning Glass (F), and
Scanning Glass (B) according to the message on the display.
And click "OK".
4. Reverse Reference Plates to white according to the message
on the display.
And click "OK".
5. Set the accessory Shading Sheet or Shading Sheet
(Part No.: See 14.8.) on the Hopper in landscape
orientation.
6. And click "OK" to scan the Shading Sheet.
7. Reverse the Reference Plates to black according to the
message on the display. And click "OK"
8. Click "OK", and then click "Close" to return to the main
menu.
Caution Setting
1. Click "Caution Setting" on the main menu.
2. Change the parameter value on the "Caution Setting"
dialog box.
3. Click "OK" to renew the setting.
Set Default
1. Click "Set Default" on the main menu.
2. Click "Set Default" on the "Set Default" dialog box to set
the default values for "Sleep Mode", "Caution Setting",
and "Feed Speed".
3. Click "Close" to return to the main menu.
Operation
data will be overwritten in stead of the current
shading data.
only for selecting "Start Shading".
Default
15 minutes When returning back to the
Clean:
20000
Replace:
350000
94
Remarks
Ready Mode from the Sleep
Mode, execute "Sleep
Mode" for Test (9.3.6) on the
main menu, and then click
"STOP" on the "Sleep
Mode" dialog box.
This item is available only if
the optional Imprinter is
installed to the scanner.
1. Before executing the
shading function, be sure to
clean the Scanning Glass
(F), Scanning Glass (B),
and rollers, and conveyors
related to conveying
documents
.
2. Until this process is
completed, don't stop the
process by opening any
doors or turning off the
scanner.

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents