8.5.19. Discharge Brush
1. Remove the Inner Cover C. (See 8.5.18.)
2. Remove the 2 screws that fasten the Discharge Brush.
8.5.20. Conveyor Motor
1. Remove the Drive Belt. (See 8.5.11.)
2. Remove the Inner Cover C. (See 8.5.18.)
3. Remove the Inner Cover L.
4. Remove the 2 screws that fasten the Heatsink for Conveyor
Motor.
5. Remove the 2 screws that fasten the Conveyor Motor in place.