10.3. Requirement After Parts Replacement

Replaced circuit board assembly or part
IC0007 (Flash memory on CONTROL Board) or
CONTROL Board
IC0004 (EEPROM on CONTROL Board) or CONTROL
Board
Starting Sensor or STARTING SENSOR Board
USS Waiting Board
USR Board
Optical Unit Front
Optical Unit Back
Reference Plate (F)
Reference Plate (B)
Drive Roller
Exit Roller
Others (when assembling or disassembling parts which
will affect the scanning positions.)
BENT PAPER S(L) SENSOR Board
BENT PAPER S(R) SENSOR Board
BENT PAPER R(L) SENSOR Board
BENT PAPER R(R) SENSOR Board
Required adjustment
1. Adjust Shading.
1. Adjust Shading.
2. Adjust Individual position manually, as required.
3. Execute Double Feed (See 9.3.7) to adjust double
feed sensitivity.
4. Execute Bent Paper Sensor (See 9.3.7.) to adjust
sensor level.
5. Set USB ID. (See 9.3.7.)
Note:
When the initial settings to this product are other than
the default (factory setting), this scanner will require
the resetting.
 (Item)
Sleep Mode
Caution Setting (Roller Cleaning Timing)
Caution Setting (Roller Replacement Timing) 350,000
Feed Speed
1. Adjust Vertical Position (for Front and Back) and
Length in individual Position or adjust All Position
1. Execute Double Feed (See 9.3.7) to adjust double
feed sensitivity.
1. Execute Double Feed (See 9.3.7) to adjust double
feed sensitivity.
1. Adjust Shading.
2. Adjust All Position or the following adjustment should
be needed.
a. Adjust Front Vertical Position in Individual
Position.
b. Adjust Front Horizontal Position in Individual
Position.
1. Adjust Shading.
2. Adjust All Position or the following adjustment should
be needed.
a. Adjust Back Vertical Position in Individual Position.
b. Adjust Back Horizontal Position in Individual
Position.
1. Adjust Shading.
1. Adjust Shading.
1. Adjust Vertical Position (for Front and Back) and
Length in individual Position or adjust All Position.
1. Adjust Vertical Position (for Front and Back) and
Length in individual Position or adjust All Position
1. Adjust the following adjustment or All Position.
a. Adjust Front Vertical Position in Individual
Position.
b. Adjust Front Horizontal Position in Individual
Position.
c. Adjust Back Vertical Position in Individual
Position.
d. Adjust Back Horizontal Position in Individual
Position.
1. Execute "Bent Paper Sensor" (See 9.3.7.) to adjust
sensor level.