Item
Bent Paper
1. Click "Bent Paper Sensor" on the main menu.
Sensor
2. Lay the Shading Sheet (See 14.8.) on the ADF Door, which
covers all Bent Paper Sensors on the BENT PAPER S (L)
SENSOR Board, BENT PAPER S (R) SENSOR Board, BENT
PAPER R (L) SENSOR Board, and BENT PAPER R (R)
SENSOR Board as shown in Sec.5.
3. Click "Adjust Automatically" to adjust the sensor level.
(Confirm all of the sensor status is "ON".)
Note: Manual Adjustment
(1) Set a sensor value in the Sensor Level.
(2) Click "Update".
(3) Check whether "Sensor Status" for the sensor
4. Click "OK" to return to the main menu.
* USB ID
1. Click "USB ID" on the main menu to enter the "USB ID"
dialog box.
2. Click "Set" on the "USB ID" dialog box to store a new ID
number for a new replaced CONTROL Board.
3. Click "Close" to return to the main menu.
Operation
value changes to "ON".
Default
101
Remarks
*This setting is available only
for a new replaced
CONTROL Board or IC0004.