8.5.7.
POWER Board
1. Remove the Power Box. (See 8.5.6.)
2. Remove the 5 screws that fasten the Power Box Cover to the
Power Box.
3. Remove the 7 screws on the POWER Board.
4. Remove the 3 screws that fasten the Heatsink to the side of
the Power Box.
5. Disconnect the 3 connectors.
6. Pull the POWER Board from the Power Box.
8.5.8.
Ionizer Board
1. Remove the Power Box. (See 8.5.6.)
2. Remove the 2 screws.
3. Disconnect the 2 connectors to release the Ionizer Board's
unit from the scanner.