Function Code List; Basic Operation Function - Sanken SVCO6 Instruction Manual

Table of Contents

Advertisement

7-2

Function Code List

Code
Function Name
No.

Basic Operation Function

1001
Motor control mode
selection
1002
1st speed frequency
setting selection
1003
V/f pattern selection
1004
Torque boost
1005
Base voltage
1006
Base frequency
※1: The representative parameters that are suitable for various models have been input.
Data Content
1: V/f control mode
2: Speed control (speed sensorless vector control)
3: Speed control (speed sensor vector control)
4: Torque control (speed sensorless vector control)
5: Torque control (speed sensor vector control)
6: Position control (speed sensor vector control)
10: Auto tuning mode 1
11: Auto tuning mode 2
40: V•f separation control
1: Operation panel
2: External analog VIF1 voltage (0
3: External analog VIF1 voltage (0
4: External analog VIF2 voltage (0
5: External analog VIF2 voltage (0
6: External analog VIF3 voltage (0
7: External analog VIF3 voltage (0
8: External analog VIF1 current (4
9: External analog VIF2 current (4
10: External analog VIF3 current (4
11: External analog VIF1 voltage +VIF2 voltage
12: External analog VIF1 voltage +VIF3 voltage
13: External analog VIF2 voltage +VIF3 voltage
14: External analog VIF1 voltage -VIF2 voltage
15: External analog VIF2 voltage –VIF1 voltage
16: External analog VIF1 voltage-VIF3 voltage
17: External analog VIF3 voltage –VIF1 voltage
18: External analog VIF1 voltage +VIF2 current
19: External analog VIF1 voltage -VIF2 current
20: External analog VIF1 current -VIF2 voltage
21: Terminal block stepping
22: Communication
25: Pulse train input
26: External analog VIF1 forward / reverse run operation
-
(0
10V, 5V reference)
27: External analog VIF2 forward / reverse run operation
-
(0
10V, 5V reference)
28: External analog VIF3 forward / reverse run operation
-
(0
10V, 5V reference)
29: Pulse train input (subPG:option)
1: Linear pattern
2: Square-law decreasing pattern (weak)
3: Square-law decreasing pattern (strong)
0-20%(maximum voltage ratio)
200V class
0: No AVR
50-240V
400V class
0: No AVR
50-460V
0.1-600Hz
The setting values can not be changed during operation.
- 85 -
7-2
Function Code List - Basic Operation Function
Resolution
-
5V)
-
10V or potentiometer)
-
5V)
-
10V or potentiometer)
-
5V)
-
10V or potentiometer)
-
20mA)
-
20mA)
-
20mA)
User
Setting
Factory
Setting
Presets
Value
1
1
1
1
1
1
※ 1
0.1%
※ 1
1V
※ 1
0.01Hz