Cycle Completion Signal Of Simple; Figure Of Simple - Sanken SVCO6 Instruction Manual

Table of Contents

Advertisement

Example)
When operation timer T2 is running and the frequency is changed on the operation panel, make an
acceleration/deceleration according to the changed frequency, enter the changed frequency values
in to F1202.
Note 2: Since the simple scheduled operation will specify multi-speed frequency in each timer, the multi-speed
changes made for control circuit input terminals will be noneffective.

7) Cycle completion signal of simple

If a control terminal output function is set in cycle completion of simple
F1509
F1511 is 3), before the operation timer T0 stops the inverter or enters into DC braking and braking
-
excitation, the open-circuit output of collector between control circuit output terminal and DCM1 & 2 is set to
ON and is about 200ms. Please put the external action command to OFF after one cycle is completed, or use it
when peripheral equipments and the programs are required to be synchronized.
Note 1: There is an output when the cycle completion signal of simple scheduled operation passes the T0. When an
output is not wanted, make a setting beyond F1509-F1511=3, or set the operation timer T0 to 0.0s.
Note 2: On the last operation timer when the total cycle (simple scheduled operation repetition count) is completed,
when the inverter stops or starts DC braking and braking excitation, the cycle completion signal which has
no relationship with the timer status will be ON.
Output terminal DO1~3
Various relay output

8) Figure of simple

scheduled
The following figure summarizes the correspondence between the actions of simple
function codes.
Operation timing T0
Multi-speed frequency 1
Forward/reverse, acceleration/deceleration time: F2221
Repetition count: F2202=0
operation
scheduled
1 cycle
When free run stops
operation and function code setting
T15: F2203
F2217=0
65000s
-
-
-
15: F2101
F2115=0
599Hz
-
-
-
250 (0: without limit)
-
- 193 -
Deceleration Stop
Inverter stops or
under DC braking and braking excitation
about 200ms
about 200ms
When deceleration stops, DC braking stops
and braking excitation stops
F2235
-
7-3
Description of Functions
operation (any one of
scheduled
operation and the
scheduled

Hide quick links: