Table of Contents

Advertisement

1.8 MINIMUM SAFETY DISTANCES

Install the product in compliance with the recommended safety distances
from heat sensitive or infl ammable materials and not infl ammable, from
load bearing and other walls and also from wooden elements, furniture,
etc.
In the case of fl ooring that is heat sensitive or infl ammable the fl oor
must be protected with non-combustible insulating material, e.g. sheets
of steel plate, marble, tiles, etc.
The minimum distances are:
A
10 cm from the wall behind the stove
B
20 cm from the side wall
80 cm in the heat radiation area and from the hot air fan
C
outlet
D
50 cm fl oor protection
E
30 cm (measured from the inner edge of the door)
F*
5 cm from the fl ue gas outlet on the rear wall
Connection to the fl ue must respect minimum safety distances from
heat-sensitive structural components or infl ammable materials (wood
panelling, beams or ceilings, etc) shown in fi gures.
* = Values referred to the use of original Gruppo Piazzetta fl ue pipes;
if other pipes are used, the safety fi re regulations or fi re codes of
reference are applicable.
a
Keep any combustible product such as wooden furniture,
curtains, carpets, combustible liquids, etc. well away from the
stove when it is lit (minimum distance 80 cm).
a
It is recommended that greater distances than those indicated
above be left all round the stove to make any necessary work
on the appliance easier.

1.9 FLUEWAY

a
The pellet stove is not the same as other stoves. It has a forced draught of fl ue gas by a fan, which keeps the fi rebox in a vacuum
and the entire fl ueway slightly pressurised. For this reason the fl ue must be completely airtight and correctly installed to ensure both
trouble-free operation and user safety.
• The fl ueway must be made by specialised personnel or fi rms, as outlined below.
• The fl ue must be installed in such a way as to guarantee that periodic cleaning can be carried out without dismantling any parts whatsoever.
• Pipes should always be sealed with silicone (not cement-based sealants) or specially adapted gaskets/seals, which retain their strength and
elasticity at high temperatures (250°C), and should be fi xed with 3.9 mm ø self-tapping screws.
a
Using the relative pipe clips, fi x the fl ue to the wall so that it does not weigh on the smoke fan.
d
Do not install dampers or valves that could block the passage of fl ue gas.
d
Do not connect to a fl ueway into which other appliances (boilers, extractor hoods, etc.) discharge fumes or vapours.
Fig. 16
F*
B
F
. 17
IG
H07025410 / DT2000678 – 00
Rear wall
A
STOVE
D C
E
E
Floor protection
Heat radiation area
F
. 18
IG
DT2030335-00
DT2011553-02
B
DT2032225-00
DT2032226-00
DT2010229-05