7.0 MAINTENANCE
Pursuant to current regulations on the safety of electrical equipment, you must contact a Piazzetta Group After-Sales Service Centre or a qualifi ed
electrician for all and any work connected with installation, maintenance or servicing that involves access inside the cladding or the smoke chamber.
Maintenance is to be considered compulsory for correct and effi cient stove operation. If maintenance is not carried out with the recommended
frequency, stove performance could suffer. The manufacturer will not be responsible for stove deterioration or malfunction if due to poor maintenance.
All maintenance work (cleaning, any replacements, etc.) must be carried out when the stove is shutdown, completely cold and the supply cable
disconnected.
a
The frequency of cleaning depends on how much the stove is used and the quality of the fuel.
7.1 CLEANING THE GRATE AND THE GRATE SUPPORT
Clean the grate area periodically (approx. once every two days) and
whenever the stove is to be lit:
- remove the grate baffl e plate and lift out the grate;
- remove any ash or other material that may have built up, taking
particular care to free any clogged holes using a sharp pointed tool;
- make sure the "ignition hole", located on the rear of the grate, is kept
clean;
- check the grate support and remove any ash.
a
After cleaning and before lighting the stove, check that the
grate is correctly inserted and pushed back towards the lower
rear baffl e. Refi t the grate baffl e plate.
7.2 CLEANING THE ASH TRAY
Every two days, check the ash drawer to see if it needs emptying.
To dispose of the ashes, refer to the paragraph "DISPOSAL OF ASHES".
48
Fig. 61
Grate baffle plate
Fig. 62
H07025410 / DT2000678 – 00
Grate
Ash pan
IGNITION HOLE
DT2012056-00
DT2010057-02
DT2010156-04
DT2032948-00
DT2030239-02
DT2010100-03