How To Wire Your Ceiling Fan - Emerson VOLTA CF590BQ00 Owner's Manual

54” wet location ceiling fan
Hide thumbs Also See for VOLTA CF590BQ00:
Table of Contents

Advertisement

BP7513 Volta CF590
1/5/16
If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.
!
To avoid possible electrical shock, be sure electricity
is turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is grounded,
contact a licensed electrician for advice, as it must be
grounded for safe operation.
7.1
Connect the green grounding lead from the hanger ball
and the green grounding lead from the hanger bracket
to the grounding conductor of supply (this may be a
bare wire or wire with green colored insulation).
Securely connect wires with wire connectors (supplied
in parts bag) (Figure 26).
!
This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson Electric Co. Substitution of parts or
accessories not designated for use with this product
by Emerson Electric Co. could result in personal injury
or property damage.
7.2
Securely connect the receiver white wire (AC in N) to
the supply white wire (neutral) using the wire connector
(supplied in parts bag) (Figure 27).
10:52 AM
Page 15

7. How to Wire Your Ceiling Fan

WARNING
WARNING
GROUND WIRE
GREEN GROUND
WIRE FROM
HANGER BALL
GREEN GROUND
WIRE FROM
HANGER BRACKET
ANTENNA
Figure 26
RECEIVER
WHITE WIRE
(AC in N)
SUPPLY
WHITE WIRE
(Neutral)
Figure 27
Please contact 1-800-654-3545 for further assistance
15
emersonfans.com