Summary of Contents for Emerson PENBROOKE SELECT CF5100BS00
Page 1
Venetian Bronze CF5100VS00 - Vintage Steel 20.2 Net Weight: Lbs. Questions, problems, missing parts: Before returning to the store call Emerson Electric Customer Service 8 a.m. - 6 p.m., Eastern, Monday-Friday 1-800-654-3545 Part No. F40BP74800000 Form No. BP7480 www.emersonfans.com Revision: 131218...
Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson could Additional Safety Instructions for Installation result in personal injury or property damage.
Emerson Electric Co. Substitution of parts or Accent Light Harness accessories not designated for use with this product Switch Cup by Emerson Electric Co. could result in personal injury or property damage. Switch Cup Assembly (Use w/Manual Switches) Check to see that you have received the following parts: NOTE: If you are uncertain of part description, refer to exploded view illustration.
BP7480 CF5100 PENBROOKE SELECT 12/18/13 10:35 AM Page 4 1. Unpacking Instructions (continued) This Manual Is Designed to Make it as Easy as Possible for You to Assemble, Install, Operate and Maintain Your Ceiling Fan Tools Needed for Assembly Installed Wire Length Wire Size A.W.G.
BP7480 CF5100 PENBROOKE SELECT 12/18/13 10:35 AM Page 5 3. Ceiling Fan Assembly #10-24 x 12mm ROUND HEAD BLADE SCREW (4) 9/16" FLAT Mount the fan blade (sold separately) using the four WASHER #10-24 x 12mm round head screws and flat washers (4 per blade/flange) (supplied) to secure flange to blade (Figure 1).
Page 6
BP7480 CF5100 PENBROOKE SELECT 12/18/13 10:35 AM Page 6 3. Ceiling Fan Assembly (continued) Installation of Switch Cup PULL CHAIN SWITCH Assembly for Manual Control Engage the connector of the switch cup assembly with MOTOR the motor connector (Figure 4). The two connectors are CONNECTOR keyed and color-coded and must be mated correctly SWITCH CUP...
Page 7
BP7480 CF5100 PENBROOKE SELECT 12/18/13 10:35 AM Page 7 3. Ceiling Fan Assembly (continued) Remove the hanger ball by loosening the setscrew in HANGER BALL the hanger ball until the ball falls freely down the downrod (Figure 7). Remove the pin from the downrod, then remove the hanger ball.
Page 8
BP7480 CF5100 PENBROOKE SELECT 12/18/13 10:35 AM Page 8 3. Ceiling Fan Assembly (continued) 3.10 #8-32 x 1-1/4" Screw two #8-32 x 1-1/4” threaded studs (provided) into THREADED STUD (2) the motor (Figure 10). Leave approximately 7/8” of the 7/8" stud extending above the motor.
BP7480 CF5100 PENBROOKE SELECT 12/18/13 10:35 AM Page 9 4. How to Hang Your Ceiling Fan CEILING WARNING The fan must be hung with at least 7' of clearance from floor to blades (Figure 13). AT LEAST Figure 13 FLOOR WARNING The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs.
BP7480 CF5100 PENBROOKE SELECT 12/18/13 10:35 AM Page 10 4. How to Hang Your Ceiling Fan (continued) NOTE: CEILING COVER, Carefully lift the fan and seat the hanger ball/ SUPPLY WIRES AND FAN downrod assembly on the hanger bracket that was just WIRES OMITTED FOR CLARITY.
Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage. 7. Switch Cup - Manual Control...
Emerson Electric Co. Substitution of parts or WARNING accessories not designated for use with this product by Emerson Electric Co. could result in personal injury The use of any other control not specifically approved or property damage. for this fan could result in fire, shock and personal injury.
10. Accent Light Harness Installation 10.1 COUPLER NOTE: If you are planning to install an optional COVER Emerson Accent Light Fixture on your ceiling fan, DOWNROD DO NOT REMOVE THESE remove the coupler cover at this time for WIRE CONNECTORS installation.
Emerson Accessory must be installed in order to LIGHT KIT & operate the light. MOTOR ASSEMBLY CONNECTORS It is recommended to use either an Emerson SR600, Figure 23 SW605 or SR650 Transmitter and the RCK55 Receiver. See RCK55 for installation instructions of the control.
BP7480 CF5100 PENBROOKE SELECT 12/18/13 10:35 AM Page 15 12. Trouble Shooting WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN. TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fuse or circuit breaker blown. 1.
BP7480 CF5100 PENBROOKE SELECT 12/18/13 10:35 AM Page 16 13. Repair Parts (NOT SUPPLIED) Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: • PART NUMBER •...
BP7480 CF5100 PENBROOKE SELECT 12/18/13 10:35 AM Page 17 13. Repair Parts Listing emersonfans.com Please contact 1-800-654-3545 for further assistance U.L. Model No.: CF5100...
Page 18
BP7480 CF5100 PENBROOKE SELECT 12/18/13 10:35 AM Page 18 NOTES U.L. Model No.: CF5100...
What We Will Do To Correct Problems: If during the one (1) year warranty period the motor or any component or accessory of your Emerson Ceiling Fan is defective in materials or workmanship, or if during the expected lifetime of the Emerson Ceiling Fan (when used in accordance with the User Manual or other instructions) the motor is defective in materials or workmanship, you must contact Emerson during the applicable warranty period.
Page 20
12/18/13 10:35 AM Page 20 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St. Louis, MO 63136 Questions, problems, missing parts: Before returning to the store call Emerson Electric Customer Service 8 a.m. - 6 p.m., Eastern, Monday-Friday 1-800-654-3545 www.emersonfans.com...
Need help?
Do you have a question about the PENBROOKE SELECT CF5100BS00 and is the answer not in the manual?
Questions and answers