Emerson CF760AB00 Owner's Manual
Emerson CF760AB00 Owner's Manual

Emerson CF760AB00 Owner's Manual

60” designer ceiling fan

Advertisement

Quick Links

BP7287 60" DESIGNER FAN
READ AND SAVE THESE INSTRUCTIONS
60" DESIGNER
Ceiling Fan
Owner's Manual
CF760AB00
CF760AW00
CF760WW00
WARNING: To avoid fire, shock, and serious personal injury, follow these instructions.
1. Read your owner's manual carefully and keep it for future reference.
2. Before servicing or cleaning unit, switch power off at service panel and lock service panel
disconnecting means to prevent power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the
service panel.
3. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off
the power to the ceiling fan before servicing.
4. Do not put anything into the fan blades while they are turning.
5. Do not operate reversing switch until fan blades have come to a complete stop.
Additional Safety Instructions for Installation
1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not
operate fan without blades.
2. The installation is to be in accordance with the National Electrical Code, ANSI/NFPA 70-1999 and
Local Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be
grounded as a precaution against possible electrical shock. Electrical installation should be made
or approved by a licensed electrician.
3. The outlet box and joist must be securely mounted and capable of reliably supporting at least 50
pounds. Use only U.L. outlet boxes listed as "Acceptable for Fan Support", and use the mounting
screws provided with the outlet box. Most outlet boxes commonly used for support of light fixtures are
not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
4. The downrod furnished with the fan provides the minimum recommended floor to fan blade
clearance for an 8 foot ceiling.
5. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental
contact with the fan blades.
6. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not
know enough about electrical wiring, have your fan installed by a licensed electrician.
WARNING: To avoid fire, shock or injury, do not use an Emerson or any other brand of control not
specifically approved for this fan.
WARNING: This product is designed to use only those parts supplied with this product and/or any
accessories designated specifically for use with this product by Emerson Electric Co. Substitution of
parts or accessories not designated for use with this product by Emerson Electric Co. could result in
personal injury or property damage.
WARNING: To Reduce the risk of personal injury, do not bend the blade flange when installing the
blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between
rotating fan blades.
Part No. F40BP72870000
3/10/05
10:42 AM
Page 1
Net Weight:
Model No.
CF760BS00
CF760ORB00
WARNING
!
Safety Instructions
30.0
Lbs.
CF760PW00
CF760WB00
Form No. BP7287

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CF760AB00 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Emerson CF760AB00

  • Page 1 Page 1 READ AND SAVE THESE INSTRUCTIONS 60” DESIGNER Ceiling Fan 30.0 Owner's Manual Net Weight: Lbs. Model No. CF760AB00 CF760BS00 CF760PW00 CF760AW00 CF760ORB00 CF760WB00 CF760WW00 WARNING WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1.
  • Page 2: Unpacking Instructions

    BP7287 60" DESIGNER FAN 3/10/05 10:42 AM Page 2 This Manual Is Designed to Make it as Easy as Possible for You to Assemble, Install, Operate and Maintain Your Ceiling Fan Tools Needed for Assembly Installed Wire Length Wire Size A.W.G. Up to 50 ft.
  • Page 3: How To Put Your Ceiling Fan Together

    BP7287 60" DESIGNER FAN 3/10/05 10:42 AM Page 3 NOTE: Place the parts from the loose 2. Remove the fan assembly from the parts bags in a small container to keep protective plastic bag. Place the fan them from being lost. If any parts are assembly into the upper foam pad with missing, contact your local retailer or the bottom of the motor facing up.
  • Page 4 BP7287 60" DESIGNER FAN 3/10/05 10:42 AM Page 4 4. Reinstall the hanger ball (Figure 4) on WARNING the downrod as follows. Route the three 80” motor leads through the To avoid possible fire or shock, do not hanger ball. Position the pin through pinch wires between the switch cup assembly and the switch cup plate.
  • Page 5: Electrical Requirements

    BP7287 60" DESIGNER FAN 3/10/05 10:42 AM Page 5 10. Loosely attach one blade assembly to seat properly on the motor hub, the motor hub using two 1/4-20 x 1/2” loosen the adjacent flange screws, re- Phillips oval head flange screws. engage and reseat the flanges, then Make sure the screws are NOT tighten the screws again.
  • Page 6: How To Hang Your Ceiling Fan

    BP7287 60" DESIGNER FAN 3/10/05 10:42 AM Page 6 How to Hang Your Ceiling Fan WARNING OUTLET The fan must be hung with at least 7' of clearance from floor to blades (Figure 9). CEILING TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET Figure 10...
  • Page 7: How To Wire Your Ceiling Fan

    BP7287 60" DESIGNER FAN 3/10/05 10:42 AM Page 7 How to Wire Your Ceiling Fan If you feel that you do not have enough WARNING electrical wiring knowledge experience, have your fan installed by a Check to see that all connections are tight, including ground, and that no bare licensed electrician.
  • Page 8: Maintenance

    BP7287 60" DESIGNER FAN 3/10/05 10:42 AM Page 8 Using Your Ceiling Fan 1. Restore electrical power to the outlet Your fan model is equipped with a 4- box by turning the electricity on at the position, 3-speed pull chain switch. The main fuse box.
  • Page 9: Troubleshooting

    BP7287 60" DESIGNER FAN 3/10/05 10:42 AM Page 9 WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN. Trouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not 1. Fuse or circuit breaker 1.
  • Page 10: How To Order Repair Parts

    BP7287 60" DESIGNER FAN 3/10/05 10:42 AM Page 10 Repair Parts Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: • PART NUMBER • NAME OF ITEM •...
  • Page 11 BP7287 60" DESIGNER FAN 3/10/05 10:42 AM Page 11 Repair Parts Listing...
  • Page 12: Limited Warranty

    BP7287 60" DESIGNER FAN 3/10/05 10:42 AM Page 12 LIMITED WARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. You must be the original purchaser or user of the product to be covered. What The Period Of Coverage Is: As it applies to the motor, this warranty will last for thirty years from the date you purchased your ceiling fan.

Table of Contents