E805-
Fan failure
0000
The fan is faulty.
Fixing drive circuit failure
E808-
- The heater does not turn on. - A fixing drive
0000
motor failure was detected.

Canon iR3035 Trouble Error Codes

Code
The temperature of the fixing assembly is
abnormally high.
While startup control is under way, the
reading of the main thermistor is less than
30 deg C continuously for 200 msec or more
1 sec after the start of power supply. While
startup control is under way, the reading of
E000-
the main thermistor is less than 70 deg C
0001
continuously for 200 msec or more 2 sec
after the start of power supply. While startup
control is under way, the reading of the main
thermistor is less than 120 deg C
continuously for 200 msec 6 sec after the
start of power supply. The startup control
does not end 30 sec after the start of power
supply.
The temperature of the fixing assembly is
E001-
abnormally high.
0000
The reading of the main thermistor is 250
deg C or more continuously for 200 msec.
The temperature of the fixing assembly is
E001-
abnormally high.
0001
The hardware circuit detects overheating of
the main or sub thermistor for 200 msec.
The temperature of the fixing assembly is
E001-
abnormally high.
The reading of the sub thermistor is 295 deg
0002
C or more continuously for 200 msec.
The rise in temperature of the fixing
assembly is faulty
E002-
While startup control is under way, the
0000
reading of the main thermistor is less than
115 deg C continuously for 400 msec 1.3
sec after it has indicated 100 deg C. While
Description
8
- Check the fan connector. - Replace the
fan. - Replace the DC controller PCB.
- Check the connector of the fixing film
unit. - Replace the fixing film unit. -
Replace the fixing drive motor. - Replace
the DC controller PCB. - Replace the
power supply PCB.
Reset the condition in service mode:
COPIER>FUNCTION>CLEAR> ERR.
Replace the main thermistor. Replace the
DC controller PCB.
Reset the condition in service mode:
COPIER>FUNCTION>CLEAR> ERR.
Replace the main thermistor. Replace the
DC controller PCB.
Reset the condition in service mode:
COPIER>FUNCTION>CLEAR> ERR.
Replace the DC controller PCB.
Reset the condition in service mode:
COPIER>FUNCTION>CLEAR> ERR.
Replace the sub thermistor. Replace the
DC controller PCB.
Reset the condition in service mode:
COPIER>FUNCTION>CLEAR> ERR.
Replace the main thermistor. Replace the
DC controller PCB.
Remedy