4.1 Notes when service

4.1.1 Secondary battery

Host mathine include secondary battery which backup FAX's snd Send images at the time of blackout.
The external specification of this is as follows.
- When a battery is cut, the image backup data for FAX and Send disappear. You can back up the image files over one hour by charging battery more than two
hours.
- Because red LED(LED10) on the controller turns on, You can confirm the state that backup functions.

4.2 Reference matter in market service

4.2.1 Recommended setting of system management information

When multiple users use a host machine, it is necessary to advise each user to set the system management information.
Setting ID and password of system administrator on the operation unit under [Additional Functions] > [System Management Set] > [System Manager Info. Set.]
has an effect of restraining the third person from falsifying information, for the ID and password are required when a user carries out an important setting of the
host machine.
Under the environment that the setting is not done, if a user who does not sufficiently know operation situation of the host machine tries to change the setting,
following troubles may occur.
- When the user changes [User ID Management] from [off] to [on], copying operation cannot be done unless ID and password are input.
- When each setting is changed on the network from RUI, that enables to falsify data of address book or delete log.
- When TCP/IP fixed address is changed on the network setting, printing operation via network cannot be done until the port setting is changed.
- When usage restriction of USB device is changed to [on], printing operation via USB becomes disabled.

4.2.2 Department ID Management

Function:
If Department is registered in Department ID Management, users are required to input the Department ID and password when inputting data from the operation
unit of iR host machine. Also, the registration enables to restrict usage and control the usage number of times of Total Parts, Copy, B&W Scan, Color Scan, or
Print.
Setting method:
Register Department ID in Department ID Management under Additional Functions>System Setting.
Operation outline:
Department ID can be registered in [Department ID management] from the operation unit of iR host machine even though [System Manager Settings] is not done.
When registering data in [Department ID Management] using RUI, you need to register yourself as a system manager in [System Manager Settings] and login
as a system manager.

4.2.3 Deleting All CA Certificate

You can erase All CA certificate which a user installed collectively when You carry out the following service mode.
COPIER > Function CLEAR > CA-KEY
Reboot is necessary after practice.
The CA certificate returns to a state at the time of the factory shipment.

4.3 Related Error code

4.3.1 The viewpoint of Error Codes

Error codes are four columns of codes that are recorded in transmission error report or reception error report when error happened.
It is able to check error codes in detailed information screen of the job log of the system status screen.
An error code is four columns of #XXXX with the output paper, but it is displayed with three columns of #XXX on the touch panel.
Refer to the following entry about error codes.
Error code details see below.