GbE cables must be at least CAT-5E certified for
1000 Mb/sec. use.
Serial interface
The RS-232 serial port provides support for
remote monitoring and management through a
command line interface. It is set at the factory at
115,200 bps.
Installation instructions
1
Install the iPBridge 2500C in the target device.
(See the board layout diagram below)
2
Connect SCSI devices to the iPBridge. and
attach CAT 6 or CAT 5E cables to the GbE data
Exhibit 1.2-1 ATTO iPBridge 2500C faceplate
SCSI ports
SCSI LEDs
SCSI Port 0
SCSI Port 1
7
ATTO Technology Inc. iPBridge Installation and Operation Manual
Pin outs of the RJ11 connector, part number CBL-
0911-001 are
Pin Description
2
TXD
3
Ground
4
RXD
5
Ground
port(s) on the iPBridge. (For details, refer to
Appendix,
3
Connect to power.
4
Configure the iPBridge using the instructions in
Configuring the iPBridge
Ethernet data ports
Data Port 0
Data Port 1
Ethernet port link and activity LEDs
Cabling, on page iii).
on page 9.
Ethernet
management
RS-232 port
port
RS-232
Management Port
the
Fault LED
Fault