Troubleshooting; Inside Out Method; Check The Host Event Log; Check The Ipbridge Event And Trace Logs - ATTO Technology iPBridge 2500C Installation And Operation Manual

Atto user manual ipbridge 2500c/r/d
Hide thumbs Also See for iPBridge 2500C:
Table of Contents

Advertisement

If it is clear that a particular component system is at fault in a problem situation, go directly to that
component. If it is not clear, the best approach is to troubleshoot using the inside-out method.
You may check on the status of your iPBridge using
the ExpressNAV interface. Refer to
pages
on page 23 to see which pages may contain the
information you need. You may also look for
information by using the diagnostic CLI commands,
enumerated in
Diagnostic commands
the Advanced page of the ExpressNAV interface, or by

Inside out method

To troubleshoot using the inside out method, begin with the device(s) connected to the iPBridge first, then work
your way out.
• SCSI devices
• iPBridge SCSI ports
iPBridge internal configuration
iPBridge Ethernet/IP ports
• LAN/WAN
• Ethernet host adapter or NIC in host
• iSCSI OS driver

Check the host event log

Check the event log on the host. Look for the most
recent entries and determine what could be causing a

Check the iPBridge event and trace logs

Check the iPBridge event log through the CLI. Refer
to
Diagnostic commands
most recent entries and determine what could be

Visually inspect LEDs

Light Emitting Diodes (LEDs) are located on both
sides of the iPBridge
If there is a non-fatal power supply problem, or if a
problem is detected before shut down occurs, the
Fault LED flashes. The Fault LED also flashes briefly
during start up.
27
ATTO Technology Inc. iPBridge Installation and Operation Manual

6 Troubleshooting

ExpressNAV
on page 43, in
• OS
• Application
on page 43. Look for the
using the CLI directly (refer to
based interface
on page 35.)
To start and use the ExpressNAV interface, including
how to access the version information, refer to
ExpressNAV interface
problem, then go to that event and continue
troubleshooting.
causing a problem. Then go to that event and continue
troubleshooting.
Each SCSI bus has its own LED to show activity on
that bus. The LED blinks when I/O is occurring and is
solid when there is heavy activity.
The Fault LED lights yellow when the iPBridge is
turned on, then immediately goes dark. Software
activates the LED if there is a system error.
CLI provides ASCII-
ATTO
on page 21.