Fireplace Settings; Main Burner; Proflamme 2 Remote Control - J. A. Roby loo RGR-25 Installation And Operation Manual

Direct-vented
Hide thumbs Also See for loo RGR-25:
Table of Contents

Advertisement

4. FIREPLACE SETTINGS

4.1. MAIN BURNER

The fireplace includes an adjustment for the air/gas premix (figure 4.1). It can be used when converting
from natural gas (NG) to propane gas (LP) or vice versa. For natural gas, the air/gas premix adjustment
screw must be completely screwed (toward the inside of the combustion chamber). For propane gas, the
adjustment screw must be unscrewed (do not remove it completely).
The air/gas premix adjustment screw is located under the combustion chamber. It can be accessed
through the small door located at the bottom (figure 4.1).
The screw must always remain in the threaded hole; never fully remove it.

4.2. PROFLAMME 2 REMOTE CONTROL

The Proflamme2 remote control allows you to control the following functions on your gas fireplace:
Turning the main burner on/off.
Modulating the main burner flame (6 levels).
Controlling the thermostat and Smart thermostat functions.
Technical data:
Supply voltage:
Room temperature range
Radio frequency
49
CAUTION
Figure 4.2.a
Figure 4.1
4.5 V (3 x 1.5 V AAA batteries)
0°C to 50°C (32°F to 122°F)
315 MH

Advertisement

Table of Contents
loading

Table of Contents