1.4 Generic Modules

The generic modules of the Router 6000 include the main control board –RPU2, or RPU2(H),
PSU, FAN, and FICs, which are described in the following subsections.

1.4.1 RPU2

Figure 1-5 RPU2
I. Specifications
Table 1-2 RPU2 specifications
Item
Fixed interface
Processor
Boot ROM
NVRAM
DDR SDRAM
Flash
Note:
SDRAM is the memory where the communication data between the system and CPU
is stored.
NVRAM is the place where the alarm records are stored.
Flash functions as the major file storage medium to store application program files,
anomaly information, and configuration files.
Boot ROM stores the boot program files.
2 x 10/100/1000 Mbps electrical Ethernet interfaces
1 x 10/100/1000 Mbps Ethernet interface (providing both electrical
and fiber-optic connectors)
1 AUX port
1 console port
CF card slot (the CF card is optional)
700 MHz
512 KB
512 KB
512 MB
64 MB
3Com Corporation