Combustion Air
Consult local building codes regarding combustion air supply.
Intake or combustion air can be supplied to the Insert in one
of two ways:
1) Outside air (O/A) supply: Remove cover from ash clean
out in existing fi replace. Place a rodent screen in place
of the cover. Install the Insert as described in the installa-
tion section, making sure not to cover the opening of the
air inlet. When installation is complete, seal surround to
fi replace and anywhere else air may enter. This will ensure
combustion air is drawn from outside the house and into
the 9" x 2" intake at the lower rear of the appliance.
2) Room air supply: Install the Insert as described in the
installation section. When the installation is complete,
do not seal surround to fi replace. This will allow enough
combustion air to enter the fi replace cavity and the Insert.
The knockouts in the casing sides and the O/A cover can
be removed to supplement air supply (Fig.6 & 7). Once
removed, combustion air is drawn from the room into the
lower front of the Insert.
Removal: The O/A cover should be removed prior to installa-
tion. For better access, tip the Insert onto its back.
1. Using a 5/16" wrench, remove the screw securing the O/A
cover to the fi rebox (Fig. #5 & 6).
Fig. # 5
O/A Cover Screw
ALT5.CPINSB 080515-24
Fig. # 6
O/A Cover
This unit is not designed to be operated with the fi ring door
open. In addition to the obvious hazard of sparks landing on
combustibles, an open fi re door will cause the heater to draw
air from the living space and possibly cause suffocation.
The living space around the heater must be well ventilated
with good air circulation. Anything that may cause a negative
pressure can cause gases or fumes to be pulled into the liv-
ing area.
Fig. # 7
Remove Knockout
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.
9