IF SPILLAGE IS DETECTED
The cause must be discovered and the fault corrected. If the fault cannot be cor-
rected disconnect the appliance from the gas supply and seek expert advice.
Possible causes of spillage from the appliance are:- chimney restriction, down
draught or insufficient air supply to the room.
g)
After ensuring that the fire is safe to use it should be left on "High"
position to fully warm up. During this time a slight odour may be
noticed, this is due to the "newness" of the fire and will soon disappear.
3.4
Final Check
a)
Refit the Dress-guard if it has not already been re-fitted.
b)
Recheck the operation of the fire on all settings.
c)
Make sure that the User knows how to operate the fire and refer them
to the User Book.
d)
Inform the User that the Model Number for ordering parts is shown on
the Rating plate. The rating plate can be viewed at the bottom left hand
side of the rear panel.
e)
Inform the User the fire should be serviced annually for continued safe
operation.
f)
Hand this instruction booklet to the customer.
3.5

Electrical Connection

The Flavel Welcome heater is supplied with a moulded three-pin plug (3 Amp) and
approximately 1.8 metres of flexible mains cable (1mm 2 ). The appliance and
surround should therefore be located close to a suitable mains socket to enable
connection. The electrical socket MUST be easily accessible to allow
disconnection.
This heater MUST be earthed. If in any doubt consult a suitable competent person.
Connections
L = Brown
N = BlueE = Green / Yellow
Replacement fuses should be approved and conform to BS 1362.
Supplied By www.heating spares.co Tel. 0161 620 6677