Panel; Selecting The Welding Procedure (2T/4T) - Kemppi Kempact MIG 2530 Operating Manual

Hide thumbs Also See for Kempact MIG 2530:
Table of Contents

Advertisement

3.3

Panel

Adjusting voltage and wire feed speed
The welding voltage can be adjusted from 10 to 30 V, and the wire feed speed from 1 to
18 m/min. Adjust the values appropriately by using the table of guideline values on the door
of the wire compartment and by testing.
3.
1.
ON signal light
2.
Thermostat signal light
3.
Selecting welding procedure (2T/4T)
4.
MIG welding dynamics adjustment
5.
Wire feed adjustment
6.
Welding voltage adjustment
3.4

Selecting the welding procedure (2T/4T)

2T: MIG welding with double action of the start switch of the gun:
1.
Switch closed – welding starts.
2.
Switch open – welding ends.
4T: MIG welding with quadruple action of the start switch of the gun:
1.
Switch closed – flow of shielding gas starts.
2.
Switch open – welding starts.
3.
Switch closed – welding ends.
4.
Switch open – flow of shielding gas ends.
© Kemppi Oy / 1204
1.
2.
5.
4.
6.
EN