2.3

Serial number

The serial number of the unit is marked on the rating plate of the unit. The serial number
makes it possible to trace product manufacturing series. You might need the serial number
when placing spare parts orders or when planning maintenance.
2.4

Connection to the mains supply

The Kempact 2530 is equipped with a five metre mains cable without a plug. Installation of
the plug should be carried out only by a competent electrician. For fuse and cable sizes, see
the technical data in the end of this document.
2.5

Distribution network

All regular electrical devices without special circuits generate harmonic currents into
distribution network. High rates of harmonic current may cause losses and disturbance to
some equipment.
WARNING:
low voltage system, it is the responsibility of the installer or user of the equipment to ensure, by
consultation with the distribution network operator if necessary, that the equipment may be
EN
connected.
2.6

Ground cable

Fasten the earth clamp of the return current cable carefully, preferably direct onto the piece to
be welded. The contact surface of the earth clamp should always be as large as possible. Clean
the fastening surface from paint and rust. Use at least 35 mm² cables. Thinner cross-sectional
areas cause overheating of connectors.
2.7

Wire feeding mechanism components

1.
Clamp screw
2.
Clamping lever
3.
Feed rolls
4.
Gun connector (Euro)
5.
Wire guides
4
Kempact MIG 2530
This equipment does not comply with IEC 61000-3-12. If it is connected to a public
1.
2.
3.
4.
5.