Video server port
Alarm server ref. ID
Remote alarm reporting
Remote camfail reporting
Remote Startup Reporting
ARC Ping Enabled
Alarm responder port
Dial retry time (secs)
Dial count
Zone Act (Green)
Network (Yellow)
Email (Blue)
Refresh (Purple)
Dedicated Micros ©2011
This field allows the RVRC to connect to the unit through a router that
is using port forwarding e.g. if the video server does not appear on
port 80 (HTTP), to the external network. Enter the port number used
for forwarding here if required.
This is the reference name/ID that will be presented to the RVRC
viewing application. It should therefore have some significance to the
Operator.
This must be enabled for the unit to automatically connect on alarm.
Enabling this option ensures the unit reports camera failure on any of
the inputs to the RVRC.
This will send an alarm report when the unit starts up. Any system
resets will be identified.
Should the modem/router at the Alarm Receiving Centre be dormant,
the unit will 'Ping' the ARC prior to sending reporting data.
This specifies the network port number used for reporting to the
alarm server. In normal circumstances this should be left at the
default value (23).
If the initial connection attempt fails, the unit will wait for the specified
time period (in seconds) before attempting to re-connect.
This identifies the number of times the unit will attempt to connect
after a failed attempt. A setting of '0' means no limit and the unit will
continue to try and connect until successful.
Opens the Alarm Settings -> Zone Actions page.
Opens the Network Settings -> Network page.
Opens the Network Settings -> Email page.
Refreshes the current page