Note:
It is recommended that the Pre-Alarm option be set to the same value as the Pre-Trigger setting
in the "Profile Record" menu. This will ensure successful playback of high quality Pre-Trigger
images. High quality pre-trigger images will only playback properly if review (playback) starts
prior to the pre-trigger initiation.
Alarm Protect sec.
Zone Input Rule
Input
Zone OR Input
Zone AND Input
Zone NOT Input
Alarm 24hr
Entry Route Zone
Exit route Zone
Exit Terminator
Entry Initiator
Enable in Unset
Enable in Set
Dedicated Micros ©2011
This is the minimum time period in seconds (from the start of the
alarm) that is protected from being overwritten. This time will include
the alarm trigger, the pulse extension and any post alarm recording. It
will not include pre-alarm images.
This determines which input(s) will trigger the zone alarm:
This sets an input or system function as the primary alarm trigger.
Select from Disk Low, Disk Full, Panic, Archiving Slow, Archiving
Fault, Virtual 1-16, and Keyword Channel 1 (which will trigger the
Alarm if any of the programmed keywords are detected).
The Zone OR Input identifies an alternative input that can also be
used to trigger the zone alarm. This means an alarm trigger can be
received on the Zone Alarm Input or the Zone OR Input for the
zone to be activated.
The Zone AND Input identifies that an alarm trigger needs to be
received on both the Zone Alarm Input and the Zone AND Input for
the zone to be activated and the alarm action to the
automatically initiated.
The unit will only issue the alarm actions if the trigger is received on
the zone alarm input and NOT on the Zone input.
This option can be enabled for alarms that do not require change at
any time and are to remain as programmed i.e. Panic Alarm. When
this is selected, the Set, Unset and Override options are disabled.
This creates deferred alarms along a specified route while the
entry time is active. This is in compliance with BS8418 (the British
Standard for remote video reporting centres). Diverting from the entry
route during the countdown will result in the alarm being triggered
immediately. This allows staff entry without triggering an alarm prior to
switching the system to Unset mode.
This creates deferred alarms along a specified route while the
exit time is active. This is in compliance with BS8418 (the British
Standard for remote video reporting centres). Diverting from the exit
route during the countdown will result in the alarm being triggered
immediately. This allows staff to exit without triggering an alarm.
This will trigger the exit timer if the system is set. A countdown timer
will automatically start when the alarm is activated and ensure the
alarm system is not activated by other specified alarm triggers for the
Set time i.e. allowing a Guard to exit a building.
This will trigger the entry timer if the system is set. A countdown timer
will automatically start when the 'primary' alarm trigger i.e. front door,
is actioned. This ensures the alarm system is not activated by other
specified alarm triggers for the set time
Each alarm can be configured to be active when the unit is in a
specific operation mode. Enable this for the zone alarm to be active in
Unset operation mode.
Each alarm can be configured to be active when the unit is in a
specific operation mode. Enable this for the zone alarm to be active in
Set operation mode.