Vandal dome
Table of Contents

Advertisement

Pulse Ext (s)
Nuisance
Stuck Time (min)
Note:
The arrow button displayed next to each textbox allows settings to be replicated for those
cameras listed below. This will only affect the adjacent option i.e. Enabled arrow will replicate
the Enabled setting to cameras below the clicked arrow.
Reset (Red)
Relays (Green)
Status (Yellow)
Zone In (Blue)
Refresh (Purple)
Dedicated Micros ©2011
A pulse extension is used to prevent double triggers on a single
alarm. The pulse extension time starts on an alarm trigger. If that
contact is triggered again after the first alarm has finished but within
the pulse extension, the second trigger will not restart the alarm, but
will extend the current alarm duration. Enter the time in seconds for
this extension.
This is a repetitive detector value. When an alarm is received on
the unit, it will store the alarm time and monitor the number of times
the same detector is triggered within an hour period. If the detector
is triggered the number of times entered here, the unit will de-
activate this detector from triggering an alarm for an hour. The unit
will continue to monitor the detector and check how many times it
is triggered during this period. If it is again triggered more than the
amount set in the nuisance counter, it will remain de-activated for
another hour. This will continue until the trigger value falls below the
nuisance count setting. To disable this feature, leave the setting as '0'.
If any of the alarms/detectors are active for a period longer than
specified here, they will automatically be omitted. This time period is
set in minutes.
This button will restart the unit.
Opens the Alarm Settings -> Global Actions page
Opens the System Settings -> Status -> Alarm Status Page
Opens the Zone Inputs page (below).
Refreshes the current page.